1/*-
  2 * SPDX-License-Identifier: BSD-2-Clause
  3 *
  4 * Copyright (c) 2010 Alexander V. Chernikov <melifaro@ipfw.ru>
  5 * All rights reserved.
  6 *
  7 * Redistribution and use in source and binary forms, with or without
  8 * modification, are permitted provided that the following conditions
  9 * are met:
 10 * 1. Redistributions of source code must retain the above copyright
 11 *    notice, this list of conditions and the following disclaimer.
 12 * 2. Redistributions in binary form must reproduce the above copyright
 13 *    notice, this list of conditions and the following disclaimer in the
 14 *    documentation and/or other materials provided with the distribution.
 15 *
 16 * THIS SOFTWARE IS PROVIDED BY THE AUTHOR AND CONTRIBUTORS ``AS IS'' AND
 17 * ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
 18 * IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
 19 * ARE DISCLAIMED.  IN NO EVENT SHALL THE AUTHOR OR CONTRIBUTORS BE LIABLE
 20 * FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
 21 * DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
 22 * OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
 23 * HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
 24 * LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
 25 * OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
 26 * SUCH DAMAGE.
 27 */
 28
 29#ifndef	_NETFLOW_V9_H_
 30#define	_NETFLOW_V9_H_
 31
 32#ifdef COUNTERS_64
 33#define CNTR		uint64_t
 34#define CNTR_MAX	UINT64_MAX
 35#else
 36#define CNTR		uint32_t
 37#define CNTR_MAX	UINT_MAX
 38#endif
 39
 40struct netflow_v9_template
 41{
 42	int	field_id;
 43	int	field_length;
 44};
 45
 46/* Template ID for tcp/udp v4 streams ID:257 (0x100 + NETFLOW_V9_FLOW_V4_L4) */
 47struct netflow_v9_record_ipv4_tcp
 48{
 49	uint32_t	src_addr;	/* Source IPv4 address (IPV4_SRC_ADDR) */
 50	uint32_t	dst_addr;	/* Destination IPv4 address (IPV4_DST_ADDR) */
 51	uint32_t	next_hop;	/* Next hop IPv4 address (IPV4_NEXT_HOP) */
 52	uint16_t	i_ifx;	/* Source interface index (INPUT_SNMP) */
 53	uint16_t	o_ifx;	/* Destination interface index (OUTPUT_SNMP) */
 54	CNTR		i_packets;	/* Number of incoming packets in a flow (IN_PKTS) */
 55	CNTR		i_octets;	/* Number of incoming octets in a flow (IN_BYTES) */
 56	CNTR		o_packets;	/* Number of outgoing packets in a flow (OUT_PKTS) */
 57	CNTR		o_octets;	/* Number of outgoing octets in a flow (OUT_BYTES) */
 58	uint32_t	first;	/* System uptime at start of a flow (FIRST_SWITCHED) */
 59	uint32_t	last;	/* System uptime at end of a flow (LAST_SWITCHED) */
 60	uint16_t	s_port;	/* Source port (L4_SRC_PORT) */
 61	uint16_t	d_port;	/* Destination port (L4_DST_PORT) */
 62	uint8_t		flags;	/* Cumulative OR of tcp flags (TCP_FLAGS) */
 63	uint8_t		prot;		/* IP protocol */
 64	uint8_t		tos;		/* IP type of service IN (or OUT) (TOS) */
 65	uint32_t	src_as;	/* Src peer/origin Autonomous System (SRC_AS) */
 66	uint32_t	dst_as;	/* Dst peer/origin Autonomous System (DST_AS) */
 67	uint8_t		src_mask;	/* Source route's mask bits (SRC_MASK) */
 68	uint8_t		dst_mask; 	/* Destination route's mask bits (DST_MASK) */
 69} __attribute__((__packed__));
 70
 71/* Template ID for tcp/udp v6 streams ID: 260 (0x100 + NETFLOW_V9_FLOW_V6_L4) */
 72struct netflow_v9_record_ipv6_tcp
 73{
 74	struct in6_addr	src_addr;	/* Source IPv6 address (IPV6_SRC_ADDR) */
 75	struct in6_addr	dst_addr;	/* Destination IPv6 address (IPV6_DST_ADDR) */
 76	struct in6_addr	next_hop;	/* Next hop IPv6 address (IPV6_NEXT_HOP) */
 77	uint16_t	i_ifx;	/* Source interface index (INPUT_SNMP) */
 78	uint16_t	o_ifx;	/* Destination interface index (OUTPUT_SNMP) */
 79	CNTR		i_packets;	/* Number of incoming packets in a flow (IN_PKTS) */
 80	CNTR		i_octets;	/* Number of incoming octets in a flow (IN_BYTES) */
 81	CNTR		o_packets;	/* Number of outgoing packets in a flow (OUT_PKTS) */
 82	CNTR		o_octets;	/* Number of outgoing octets in a flow (OUT_BYTES) */
 83	uint32_t	first;	/* System uptime at start of a flow (FIRST_SWITCHED) */
 84	uint32_t	last;	/* System uptime at end of a flow (LAST_SWITCHED) */
 85	uint16_t	s_port;	/* Source port (L4_SRC_PORT) */
 86	uint16_t	d_port;	/* Destination port (L4_DST_PORT) */
 87	uint8_t		flags;	/* Cumulative OR of tcp flags (TCP_FLAGS) */
 88	uint8_t		prot;		/* IP protocol */
 89	uint8_t		tos;		/* IP type of service IN (or OUT) (TOS) */
 90	uint32_t	src_as;	/* Src peer/origin Autonomous System (SRC_AS) */
 91	uint32_t	dst_as;	/* Dst peer/origin Autonomous System (DST_AS) */
 92	uint8_t		src_mask;	/* Source route's mask bits (SRC_MASK) */
 93	uint8_t		dst_mask; 	/* Destination route's mask bits (DST_MASK) */
 94} __attribute__((__packed__));
 95
 96/* Used in export9_add to determine max record size */
 97struct netflow_v9_record_general
 98{
 99	union {
100		struct netflow_v9_record_ipv4_tcp v4_tcp;
101		struct netflow_v9_record_ipv6_tcp v6_tcp;
102	} rec;
103};
104
105#define BASE_MTU	1500
106#define MIN_MTU		sizeof(struct netflow_v5_header)
107#define MAX_MTU		16384
108#define NETFLOW_V9_MAX_SIZE	_NETFLOW_V9_MAX_SIZE(BASE_MTU)
109/* Decrease MSS by 16 since there can be some IPv[46] header options */
110#define _NETFLOW_V9_MAX_SIZE(x)	(x) - sizeof(struct ip6_hdr) - sizeof(struct udphdr) - 16
111
112/* #define NETFLOW_V9_MAX_FLOWSETS	2 */
113
114#define NETFLOW_V9_MAX_RECORD_SIZE	sizeof(struct netflow_v9_record_ipv6_tcp)
115#define NETFLOW_V9_MAX_PACKETS_TEMPL	500	/* Send data templates every ... packets */
116#define NETFLOW_V9_MAX_TIME_TEMPL	600	/* Send data templates every ... seconds */
117#define NETFLOW_V9_MAX_TEMPLATES	16	/* Not a real value */
118#define _NETFLOW_V9_TEMPLATE_SIZE(x)	(sizeof(x) / sizeof(struct netflow_v9_template)) * 4
119//#define _NETFLOW_V9_TEMPLATE_SIZE(x)	((x) + 1) * 4
120
121/* Flow Templates */
122#define NETFLOW_V9_FLOW_V4_L4	1 /* IPv4 TCP/UDP packet */
123#define NETFLOW_V9_FLOW_V4_ICMP	2 /* IPv4 ICMP packet, currently unused */
124#define NETFLOW_V9_FLOW_V4_L3	3 /* IPv4 IP packet */
125#define NETFLOW_V9_FLOW_V6_L4	4 /* IPv6 TCP/UDP packet */
126#define NETFLOW_V9_FLOW_V6_ICMP	5 /* IPv6 ICMP packet, currently unused */
127#define NETFLOW_V9_FLOW_V6_L3	6 /* IPv6 IP packet */
128
129#define NETFLOW_V9_FLOW_FAKE	65535 /* Not uset used in real flowsets! */
130
131struct netflow_v9_export_dgram {
132	struct netflow_v9_header	header;
133	char				*data; /* MTU can change, record length is dynamic */
134};
135
136struct netflow_v9_flowset_header {
137	uint16_t	id; /* FlowSet id */
138	uint16_t	length; /* FlowSet length */
139} __attribute__((__packed__));
140
141struct netflow_v9_packet_opt {
142	uint16_t	length; /* current packet length */
143	uint16_t	count; /* current records count */
144	uint16_t	mtu; /* max MTU snapshot */
145	uint16_t	flow_type; /* current flowset */
146	uint16_t	flow_header; /* offset pointing to current flow header */
147};
148#endif